{"product_id":"gsl-1200x-90b","title":"1200°C Hi-Pressure Tube Furnace for Inert \u0026 Oxygen Gases up to 90 Bars - GSL-1200X-90B","description":"\u003cp\u003eGSL-1200X-50B is a high-pressure tube furnace up to 1200oC @ 90 bars. The furnace consists of three-zone internal heating inside an SS310 air-tight chamber, which can accept various gases from inert to oxygen, such as Ar, N2, H2, Co, CO2, CH4, and O2.\u003c\/p\u003e\n\u003cp\u003eThe slideable explosion-proof case is built-in the outside heating vessel and the remote control is available via laptop computer\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%;\" summary=\"width: 1000px; border-width: 1px; border-color: #0099cc; border-style: solid;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.0574%;\"\u003e\n\u003cdiv\u003e Power\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 80.7377%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e208- 240VAC, Single phase, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003e5000W Max ( 30A breaker required)\u003c\/li\u003e\n\u003cli\u003eA 10-foot power cable is included without a plug\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.0574%;\"\u003e\n\u003cdiv\u003eVacuum chamber\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 80.7377%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe vacuum chamber is made of 310S alloy with water cooling jacket\u003c\/li\u003e\n\u003cli\u003eChamber size: OD 220x ID 170 x L 1200 (mm) \u003c\/li\u003e\n\u003cli\u003eWater cold flanges in the two ends are made of SS304 and are slidable\u003c\/li\u003e\n\u003cli\u003eKF40 vacuum port, gas inlet, and outlet, as well as valves, are included\u003c\/li\u003e\n\u003cli\u003eSliding protection case is included\u003c\/li\u003e\n\u003cli\u003e95 bar gas release valve is built in for safety\u003c\/li\u003e\n\u003cli\u003e12- 9 channel gas delivery system is available upon request ( click Pic 1 to order)\u003c\/li\u003e\n\u003cli\u003e16L\/minute recirculating water chiller is required (Click Pic 2 to order\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003e\u003ca href=\"https:\/\/mtimalaysia.com\/products\/gsl-lcd\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/plcmfc.jpg?v=1764850851\u0026amp;width=3840\" alt=\"2-9 Channel Gas Control System with PLC Touch Panel and PC Operation Software - GSL-LCD\" width=\"110\" height=\"73\"\u003e\u003c\/a\u003ePic. 1 \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-KJ5300_ce014ab5-3a6c-4a5e-8d2c-98d1f582abb1.jpg?v=1713289727\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-KJ5300_ce014ab5-3a6c-4a5e-8d2c-98d1f582abb1.jpg?v=1713289727\" width=\"107\" height=\"71\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003ePic. 2\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.0574%;\"\u003e\n\u003cdiv\u003eHeating Chamber\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 80.7377%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eThree-zone heating chambers are located inside a vacuum chamber.\u003c\/li\u003e\n\u003cli\u003eHeating zone: OD120 x ID 50 x L340x3 (mm) Total heating length: 1020 mm\u003c\/li\u003e\n\u003cli\u003eUniform temperature zone: ~ 450oC +\/- 2oC\u003c\/li\u003e\n\u003cli\u003eOne quartz tube (OD60 x ID50 mm) is inserted into the heating \u003c\/li\u003e\n\u003cli\u003eHeating element: FeCrAl resistance wire with YSZ coating\u003c\/li\u003e\n\u003cli\u003eMax. working temperature: 1200ºC\u003c\/li\u003e\n\u003cli\u003eGas compatible: Inert gas, H2, CO, CH4 and O2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.0574%;\"\u003e\n\u003cdiv style=\"text-align: start;\"\u003eTemperature Control\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Temperature_Control.jpg?v=1706135240\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Temperature_Control_100x100.jpg?v=1706135240\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Temperature_Control.jpg?v=1706135240\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 80.7377%;\"\u003e\n\u003cul\u003e\n\u003cli\u003e3 digital temperature controllers certified by MET and CE Certified\u003c\/li\u003e\n\u003cli\u003ePID automatic control with 30 programmable segments for control of heating \u0026amp; cooling rate and dwell time.\u003c\/li\u003e\n\u003cli\u003eBuilt-in overheating \u0026amp; broken thermocouple protection.\u003c\/li\u003e\n\u003cli\u003eOver-temperature protection and alarm allow for operation without attendant(s).\u003c\/li\u003e\n\u003cli\u003e+\/- 1 ºC temperature accuracy.\u003c\/li\u003e\n\u003cli\u003eRS485 Communications Port and software are included for PC remote operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.0574%;\"\u003e\n\u003cdiv\u003eGas control (optional)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 80.7377%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eGas pressure and flow rate control is available upon request \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.0574%;\"\u003e\n\u003cdiv\u003eFlammable Gas protection (optional)\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 80.7377%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eWhen using flammable gases in the tube furnace, one must install a flammable gas leak detector and cut off the gas supply in case of a gas leak (Pic. 1)\u003c\/li\u003e\n\u003cli\u003eFlammable gas shall be burned via an automatic burning device (Pic. 2)\u003c\/li\u003e\n\u003cli\u003eWithout MTI training and permission, never use the furnace for flammable gases\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/mtimalaysia.com\/products\/xcdh2\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/EQXCDGAS.1_4e900b8c-7952-4200-b987-a4307bb7d5c8.jpg?v=1764854260\u0026amp;width=3840\" alt=\"Honeywell UL Approved Sensepoint Hydrogen Gas Detector - XCD-H2\" width=\"96\" height=\"64\"\u003e\u003c\/a\u003e        \u003ca href=\"https:\/\/mtimalaysia.com\/products\/gsl-kr200\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/GSL-KR200R_9a98a9b1-727e-40c4-9bbf-050d156f1628.png?v=1764854708\u0026amp;width=3840\" alt=\"Flammable Gas Control and Disposal Device - GSL-KR200\" width=\"92\" height=\"61\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 19.0574%;\"\u003e\n\u003cdiv\u003eCompliance\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 80.7377%;\"\u003e\n\u003cul\u003e\n\u003cli\u003eCE certified\u003c\/li\u003e\n\u003cli\u003eNRTL or CSA certification is available upon request at the extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985143394443,"sku":"GSL-1200X-90B","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/50bar_b0781f67-e8ab-4676-a63b-7ac6761d35fd.jpg?v=1764854579","url":"https:\/\/mti-indonesia.com\/products\/gsl-1200x-90b","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}