{"product_id":"gsl-1800x-zf4","title":"Four Source High Vacuum Thermal Evaporation Coater With Dual Source10-6 torr - GSL-1800X-ZF4","description":"GSL-1800X-ZF4 is a high-vacuum evaporation coater designed for coating oxygen-sensitive metallic materials, such as Ti, Al, Ir, etc. It also can be used for coating all kinds of materials. It has four evaporation heater sources and coats two types of materials at the same time at a high vacuum up to 10-6 torr. It is an excellent and cost-effective coating machine for research labs. Note: Since May 2023, increase chamber size to easily load sample SPECIFICATIONS Input \u0026amp; Output Power Input: 208 - 240VAC, 20 A, 50\/60 Hz, single phase Total Power required: 5 KW ( including pump) Output: 0 - 8VAC max. and 200A Max. (1600 W Max. ) Vacuum Chamber Stainless steel chamber: 300mm ID. x 360 mm H, polished finish. 100 mm observation window Hinged-type door for easy sample loading Motorized shutters for each evaporation boat, One ISO-100K port for connection with a turbo pump and a gate valve. One KF16 port to connect the vacuum gauge Six CF35 ports to connect a necessary device (e.g. film thickness monitor (QCM)) Vacuum Pump ( optional) 260 L\/s turbo molecular pump Vacuum level: 5.0x10 -6 Torr ( after 40 minutes of pumping ) Limit vacuum: 5.0x10 -7 Torr ( after baking at 100 -150°C) Leaking rate: 5.0x10 -7 Pa. Vacuum Port: DN 100 ISO-K A mechanical pump ( YTP-550-LD ) is required as a backing pump to initially achieve the vacuum level of \u0026lt;1e-2 torr Evaporation Source \u0026amp; Sample Holder Four tungsten heating boats with water-cooled shrouds Tungsten heating boat, 70L x 12W x 3H (mm). Ø120 mm rotary sample holder Evaporation distance from source to sample holder is 140-200 mm The sample stage with a heating function (up to 500 °C) is optional upon request In-situ thickness monitor optional Quartz crystal microbalance is optional for thickness measurements The accuracy of thickness control is 1.0 Angstrom. Control Unit Vacuum, thickness, and power control are integrated into one control box The Control Unit is separated from the vacuum chamber for easy moving Facility Requirement Space: 250 SF with height \u0026gt; 6 feet Chilled Water: \u0026gt; 16L\/minute flowing water required for electrode cooling or using a recirculating water chiller Certificate CE certified NRTL or CSA certification is available upon request at the extra cost\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput \u0026amp; Output Power\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 208 - 240VAC, 20 A, 50\/60 Hz, single phase\u003c\/li\u003e\n\u003cli\u003eTotal Power required: 5 KW ( including pump)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput: 0 - 8VAC max. and 200A Max. (1600 W Max. )\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eVacuum Chamber\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/gatevalve.3.jpg\" rel=\"lightbox\"\u003e\u003cimg alt=\"\" height=\"60\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/gatevalve.3.jpg\" width=\"107\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel chamber: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e \u003cspan style=\"color: rgb(0, 0, 0);\"\u003e300mm ID. x 360 mm H, polished finish.\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003cli\u003e100 mm observation window\u003c\/li\u003e\n\u003cli\u003eHinged-type door for easy sample loading\u003c\/li\u003e\n\u003cli\u003eMotorized shutters for each evaporation boat, \u003c\/li\u003e\n\u003cli\u003eOne ISO-100K port for connection with a turbo pump and a gate valve.\u003c\/li\u003e\n\u003cli\u003eOne KF16 port to connect the vacuum gauge\u003c\/li\u003e\n\u003cli\u003eSix CF35 ports to connect a necessary device (e.g. film thickness monitor (QCM))\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Pump ( optional)\u003cbr\u003e\u003ca href=\"PV-DN100-LD\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" border=\"0\" height=\"61\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/DN100CFF-Suite.1.png\" title=\"\" width=\"92\"\u003e\u003c\/a\u003e\u003ca href=\"YTP-550-LD\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" height=\"59\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-YTP-550-LD-01.jpg?v=1711673089\" width=\"89\"\u003e\u003c\/a\u003e\u003ca href=\"..\/..\/..\/PfeifferVacuumPump260L.aspx\"\u003e\u003cbr\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e260 L\/s turbo molecular pump\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eVacuum level: 5.0x10\u003csup\u003e-6\u003c\/sup\u003e Torr ( after 40 minutes of pumping )\u003c\/li\u003e\n\u003cli\u003eLimit vacuum: 5.0x10\u003csup\u003e-7 \u003c\/sup\u003e Torr ( after baking at 100 -150°C)\u003c\/li\u003e\n\u003cli\u003eLeaking rate: 5.0x10\u003csup\u003e-7 \u003c\/sup\u003ePa.\u003c\/li\u003e\n\u003cli\u003eVacuum Port: DN 100 ISO-K\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eA mechanical pump (\u003ca href=\"YTP-550-LD\" rel=\"noopener\" target=\"_blank\"\u003eYTP-550-LD\u003c\/a\u003e\u003ca href=\"..\/..\/..\/EQ-YTP-550.aspx\"\u003e\u003c\/a\u003e) is required as a backing pump to initially achieve the vacuum level of \u0026lt;1e-2 torr\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003eEvaporation Source\u003cbr\u003e\u0026amp;\u003cbr\u003eSample Holder\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eFour tungsten heating boats with water-cooled shrouds\u003c\/li\u003e\n\u003cli\u003eTungsten heating boat, 70L x 12W x 3H (mm). \u003c\/li\u003e\n\u003cli\u003eØ120 mm rotary sample holder\u003c\/li\u003e\n\u003cli\u003eEvaporation distance from source to sample holder is 140-200 mm\u003c\/li\u003e\n\u003cli\u003eThe sample stage with a heating function (up to 500 °C) is \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eoptional\u003c\/strong\u003e\u003c\/span\u003e upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/chamber3.jpg\"\u003e\u003cimg alt=\"\" height=\"66\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/chamber3.jpg\" width=\"99\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/chamber4.jpg\" rel=\"lightbox\"\u003e\u003cimg alt=\"\" height=\"68\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/chamber4.jpg\" width=\"103\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/chamber2.jpg\" rel=\"lightbox\"\u003e\u003cimg alt=\"\" height=\"67\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/chamber2.jpg\" width=\"101\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eIn-situ thickness monitor optional\u003c\/span\u003e\u003cbr\u003e\u003ca href=\"TM106-LD\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" border=\"0\" height=\"45\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQTM106.5.jpg\" title=\"\" width=\"68\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eQuartz crystal microbalance is optional for thickness measurements\u003c\/li\u003e\n\u003cli\u003eThe accuracy of thickness control is 1.0 Angstrom.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eControl Unit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eVacuum, thickness, and power control are integrated into one control box\u003c\/li\u003e\n\u003cli\u003eThe Control Unit is separated from the vacuum chamber for easy moving\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFacility Requirement \u003cbr\u003e\u003ca href=\"KJ5000\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" height=\"48\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/CW5000DIfu2.jpg\" width=\"72\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSpace: 250 SF with height \u0026gt; 6 feet\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eChilled Water: \u0026gt; 16L\/minute flowing water required for electrode cooling or using a recirculating water chiller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCertificate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003eCE certified\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\u003cspan\u003eNRTL or CSA certification is available upon request at the extra cost\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985185927307,"sku":"GSL-1800X-ZF4","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/GSL-1800X-ZF41_2ff5b45f-f327-41bd-b1ae-553bdf3c7f95.jpg?v=1764855092","url":"https:\/\/mti-indonesia.com\/products\/gsl-1800x-zf4","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}