{"product_id":"ksl-1600x-h5","title":"1700°C Max. Heavy Duty Hydrogen Gas Box Furnace 16\"x16\"x16\" (65 L) - KSL-1600X-H5","description":"\u003cp\u003eKSL-1600X-H5 is a large box furnace designed for material synthesis under hydrogen or inert gas atmosphere up to 1700 ºC with a chamber dimension of 16\" x 16\" x 16\". The furnace consists of high-quality alumina fiber bricks and three sides heated Mo-alloy coil with a vacuum-sealed steel case with a water cooling jacket and automatic H2 burning system. It is an ideal tool for preparing new materials that require a reduced atmosphere, such as phosphorous and Ti alloy, and also heat-treating materials under Ar gas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Structure\u003cbr\u003e\u003cbr\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/2.33_8556bffd-4ed3-4be4-aad5-f90ecd0363dc.jpg?v=1747074778\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/2.33_8556bffd-4ed3-4be4-aad5-f90ecd0363dc_100x100.jpg?v=1747074778\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eDouble-layer stainless steel structure for maximum vacuum and safety, which can ensure a positive pressure up to 0.06MP and vacuum up to -0.1MPa\u003c\/li\u003e\n\u003cli\u003eWater cooling front door and air cooling shell\u003c\/li\u003e\n\u003cli\u003eBuilt-in pressure gauge, vacuum valves, and two gas float meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in H2 burning control system --- if the controller detects no flame in the burner, the gas delivery valve will be shut down automatically\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eInside Chamber \u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eHeated chamber: 400 x 400 x 400 mm (16x16x16 inch), 65 Liter (Max.)\u003c\/li\u003e\n\u003cli\u003eEnergy-saving 1800 - grade fibrous alumina insulation\u003c\/li\u003e\n\u003cli\u003eSealed by stainless steel with water-cooling\u003c\/li\u003e\n\u003cli\u003eThree sides heating ( Left right and back ) to ensure the best temperature uniformity.\u003c\/li\u003e\n\u003cli\u003eSiC plate is installed on the bottom, which has 100kg, Max. loading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cbr\u003eHeating Elements\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e9 sets of Mo coils heating elements are built-in and replaceable \u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eThe Mo heating element is consumable. You may order spare element by click Pic. 1 below\u003c\/li\u003e\n\u003cli\u003eWarning: Mo heating element can not be used under air or oxygen at the temperature \u0026gt; 300°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eThe heating element can be replaced by 1900 grade MoSi2 to run the furnace under oxygen and air and Inert gases up to 1700 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"K1700H2HE\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" height=\"53\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/KSL1700X-H2_HE.jpg\" width=\"80\"\u003e\u003c\/a\u003ePic. 1 \u003ca href=\"https:\/\/mtimalaysia.com\/products\/hel1800t-30360\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/EQHEL1800T.3.jpg?v=1764854144\u0026amp;width=3840\" alt=\"1800°C Grade MoSi2 Heating Element (30x360mm) - HEL1800T-30360\" width=\"74\" height=\"49\"\u003e\u003c\/a\u003ePic. 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e36 kW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eVoltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAC 208 - 240V three phases (50\/60 Hz)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCurrent\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e80 Amp (100 Amp air breaker is required)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eContinuous Working Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1600 °C ( in H2 gas or Ar gas, not recommended under N2 gas )\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMaximum Working Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1700 \u003cstrong\u003e\u003cem\u003e°\u003c\/em\u003e\u003c\/strong\u003eC (\u0026lt; 1 hr) ( in H2 gas or Ar gas, not recommended under N2 gas )\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHeating Rate\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 °C\/min\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+\/- 0.1 \u003cstrong\u003e\u003cem\u003e°\u003c\/em\u003e\u003c\/strong\u003eC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003eTemperature Control \u003cbr\u003eand\u003cbr\u003eProcessing control\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/Temperature_Control.jpg?v=1706135240\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eTemperature and processing control via touch screen computer, including\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e.Temperature control with +\/- 1 ºC accuracy.\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eTwo thermal couples are built-in: one for temperature control and one for safety monitoring \u003c\/li\u003e\n\u003cli\u003e30 programmable segments for precise control of heating rate, cooling rate, and dwell time.\u003c\/li\u003e\n\u003cli\u003eOver-temperature protection by an independent controller\u003c\/li\u003e\n\u003cli\u003eRecording and display temperature profile during operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eProcessing control includes\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003ePurging procedure for the furnace chamber\u003c\/li\u003e\n\u003cli\u003eChamber pressure control\u003c\/li\u003e\n\u003cli\u003eGas flow control\u003c\/li\u003e\n\u003cli\u003eRecording and display pressure profile during operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Flow Control and Vacuum Valve\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGas Flow Control and Vacuum Valve Two large flow meters (N2: 0~ 12L\/min, H2: 0~12L\/min) are installed in the front panel of the furnace.\u003c\/li\u003e\n\u003cli\u003eOne for purging Inert gas prior to introducing H2 gas\u003c\/li\u003e\n\u003cli\u003eOne for controlling H2 gas flow\u003c\/li\u003e\n\u003cli\u003eKF40 vacuum pumps built-in to connect a vacuum pump\u003c\/li\u003e\n\u003cli\u003eThe vacuum pump may be needed, but not included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH2 Gas Burning Control System\u003cbr\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"xcdh2\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQXCDGAS_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAn ignition device is already installed to incinerate flowing gas and detect burner temperature to ensure H2 burner is in working condition. If H2 does not burn properly, the controller will shut down the H2 gas delivery valve immediately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eWarning\u003c\/span\u003e\u003c\/strong\u003e: You must install a certified Hydrogen detector in the operation facility to alarm for hydrogen leaking by accident. Please click the link below to order a hydrogen detector from us at extra cost.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Cooling\u003cbr\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"kj5300\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/KJ5300Front.1_100x100.jpg\" style=\"margin-bottom: 16px; float: none;\" title=\"\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eA 16L\/min recirculating water chiller is installed in a bottom furnace for cooling the furnace's sealing flange. \u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCompliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE Certified\u003c\/li\u003e\n\u003cli\u003eNRTL or CSA certification is available upon request at an extra cost.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eApplication Notes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eThe pressure inside the chamber should ALWAYS be controlled at 0.01-0.02 Mpa above the standard atmospheric pressure during the entire heating process, otherwise, the oxygen in the air may backflow into the furnace chamber and cause an explosion in the worst-case scenario.\u003c\/li\u003e\n\u003cli\u003eALWAYS place the furnace in a room with the fume hood and a hydrogen detector installed.\u003c\/li\u003e\n\u003cli\u003eGood ventilation is necessary for the room in which the furnace\u003c\/li\u003e\n\u003cli\u003eExhausting Hydrogen gas in the room is forbidden.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985155944587,"sku":"KSL-1600X-H5","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/KSL-1600X-H4_main_1f777777-abc7-47b7-9670-ac04fe11440c.jpg?v=1764854707","url":"https:\/\/mti-indonesia.com\/products\/ksl-1600x-h5","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}