{"product_id":"vpc-mv-ld","title":"Precision Vacuum Pressure Regulating System with Motorized Valve , (Gauge is required but not included), 10E-6 to 760 torr - VPC-MV-LD","description":"This is a turn-key solution for precisely controlling the vacuum pressure in a vacuum chamber\/system. Benefits from the motorized valve and wide range vacuum measuring gauge, the input gas flow can be precisely regulated in order to maintain certain vacuum pressure range from 1.0E-6 to 760 Torr, guaranteed. SPECIFICATIONS Upgraeded option for MTI High-Vacuum Pumping Station High-Vacuum Pumping Station with Pfeiffer Turbo and Rotary Vane Backing Pump (Upto 1E-7 mbar at Faster Pumping Speed) - EQ-PV-HVS2-LD Controller For creating a control section in conjunction with the pressure regulating valves Simple operation with s elf-explanatory LCD display and function keys Analog\/digital inputs\/outputs and interfaces Settable PID regulating algorithm For system manufacturers, as a supplement to their own control unit Working voltage: 100~250 VAC, 50\/60 Hz universal Power Consumption: 50 W Pressure Gauge (Not INCLUDED) Flange size: DN 25 ISO-KF, stainless steel Measurement range from 3.75E-9 to 760 Torr Two gauge heads (Pirani and cold cathode) in a single case (inverted magnetron) Corrosion-resistant Maximum pressure: 3,000 Torr (refers to inert gasses) Operating temperatures: 5-55 °C Motorized Valve Flange in and out: DN 16 ISO-KF Ambient temperature: 5-40 °C (41-104 °F) Gas flow controllable range: 3.75E-6 to 937.5 Torr l\/s Operating pressure: 7.5E-9 to 1875 Torr With integrated motor control electronics Fluoroelastomer dosing sleeve Application Notes The motorized valve is used together with a control unit for controlling the pressure in a vacuum system, with a variable gas flow (upstream control) for maintaining a desired vacuum pressure. More specifically, the control valve regulates the gas inlet of the vacuum system. The valve plate moves in closing direction when the pressure in the vacuum system rises, vice and verse. Upstream control Solution This turn-key solution can be used with most of the vacuum pumps available on the market,  such as turbo, oilless\/dry, oil, diffusion pumps. It must not be used with liquid vapors. Operation Instructions\u003cbr\u003e\u003cbr\u003e\u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width: 998px; border: 1px solid #0099cc; height: 620px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc; width: 150px;\" valign=\"top\"\u003e\n\u003cbr\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eUpgraeded option for MTI High-Vacuum Pumping Station\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc;\" valign=\"top\"\u003e\n\u003cspan face=\"arial, helvetica, sans-serif\" size=\"2\" style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003cspan face=\"arial, helvetica, sans-serif\" size=\"2\" style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003ca href=\"http:\/\/www.mtixtl.com\/PfeifferVacuumPump10E-3to10E-7mbarwithKF40VacuumTubeKF25Vac-1.aspx\"\u003e\u003cimg alt=\"\" border=\"0\" class=\"product-list-img\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQPVHVSright.1.2.jpg\" title=\"\" width=\"200\"\u003e\u003c\/a\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cdiv class=\"product-list-options\"\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"http:\/\/www.mtixtl.com\/PfeifferVacuumPump10E-3to10E-7mbarwithKF40VacuumTubeKF25Vac-1.aspx\"\u003eHigh-Vacuum Pumping Station with Pfeiffer Turbo and Rotary Vane Backing Pump (Upto 1E-7 mbar at Faster Pumping Speed) - EQ-PV-HVS2-LD\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc; width: 150px;\" valign=\"top\"\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003e\u003cbr\u003eController\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/controller_unit.jpg\"\u003e\u003cimg height=\"40\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/controller_unit.jpg\" style=\"border: 1px solid black;\" width=\"60\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc;\" valign=\"top\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cspan face=\"arial, helvetica, sans-serif\" size=\"2\" style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003cspan face=\"arial, helvetica, sans-serif\" size=\"2\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eFor creating a control section in conjunction with the pressure regulating valves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eSimple operation with s\u003c\/span\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eelf-explanatory LCD display and function keys\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eAnalog\/digital inputs\/outputs and interfaces\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eSettable PID regulating algorithm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eFor system manufacturers, as a supplement to their own control unit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eWorking voltage: 100~250 VAC, 50\/60 Hz universal\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003ePower Consumption: 50 W\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc; width: 150px;\" valign=\"top\"\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003e\u003cbr\u003ePressure Gauge\u003cbr\u003e(Not INCLUDED)\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/motorized_gauge.jpg\"\u003e\u003cimg height=\"40\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/motorized_gauge.jpg\" style=\"border: 1px solid black;\" width=\"60\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc;\" valign=\"top\"\u003e\n\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eFlange size: DN 25 ISO-KF, stainless steel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eMeasurement range from 3.75E-9 to 760 Torr\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eTwo gauge heads (Pirani and cold cathode) in a single case (inverted magnetron)\u003c\/span\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eCorrosion-resistant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eMaximum pressure: 3,000 Torr (refers to inert gasses) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003eOperating temperatures: 5-55 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc; width: 150px;\" valign=\"top\"\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003cbr\u003eMotorized Valve\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/motorized_valve.jpg\"\u003e\u003cimg height=\"40\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/motorized_valve.jpg\" style=\"border: 1px solid black;\" width=\"60\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc;\" valign=\"top\"\u003e\n\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eFlange in and out: DN 16 ISO-KF\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eAmbient temperature: 5-40 °C (41-104 °F)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eGas flow controllable range: 3.75E-6 to 937.5 Torr l\/s \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eOperating pressure: 7.5E-9 to 1875 Torr\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eWith integrated motor control electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eFluoroelastomer dosing sleeve\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc; width: 150px;\" valign=\"top\"\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003eApplication Notes\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc;\" valign=\"top\"\u003e\n\u003cul\u003e\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eThe motorized valve is used together with a control unit for controlling the pressure in a vacuum system, with a variable gas flow (upstream control) for maintaining a desired vacuum pressure. More specifically, the control valve regulates the gas inlet of the vacuum system. The valve plate moves in closing direction when the pressure in the vacuum system rises, vice and verse.\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e         \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-EQ-VPC-MV.jpg\"\u003e\u003cimg height=\"149\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-EQ-VPC-MV.jpg\" width=\"291\"\u003e\u003c\/a\u003e       \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-VPC-MV-LD.jpg\"\u003e\u003cimg height=\"149\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-VPC-MV-LD.jpg\" width=\"223\"\u003e\u003c\/a\u003e      \u003cbr\u003e                                                                                                Upstream control Solution\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eThis turn-key solution can be used with most of the vacuum pumps available on the market,  such as turbo, oilless\/dry, oil, diffusion pumps.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003eIt must not be used with liquid vapors.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc; width: 150px;\" valign=\"top\"\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003cspan\u003e\u003cspan\u003e\u003cbr\u003eOperation Instructions\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"padding-left: 15px; border: 1px solid #0099cc;\" valign=\"top\"\u003e\u003cspan face=\"arial, helvetica, sans-serif\" size=\"2\" style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003ca href=\"http:\/\/www.mtixtl.com\/eq-vpc-mv-ld.aspx\"\u003e\u003cimg height=\"104\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQ-VPC-MV-LD.jpg\" width=\"139\"\u003e\u003c\/a\u003e       \u003ca href=\"..\/..\/..\/MANUAL\/EQ-VPC-MV--instructions-120814.pdf\"\u003e\u003cimg alt=\"\" border=\"0\" height=\"27\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/1-Operation_Manual.jpg\" width=\"157\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985108070539,"sku":"PV-PCMV","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/Precisionvacuumpressureregulatingsystem.1_eeef96f3-d744-46b2-97d0-314105a4d870.jpg?v=1764854263","url":"https:\/\/mti-indonesia.com\/products\/vpc-mv-ld","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}