{"product_id":"ylj-hp60-ld","title":"200C Max. 6T Hydraulic Lamination Hot Press (12x12 cm area) - YLJ-HP60-LD","description":"\u003cp\u003eYLJ-HP60-LD (updated from YLJ-HP-6T-LD) is 200°C Max. compact lamination hot press consists of 6 metric ton hydraulic press with two heated platens (120x120mm area). The temperatures of the heated platens are controlled by a digital temperature controller up to 200°C. The hot press is designed for preparing electrode \u0026amp; electrolyte of solid and flexible lithium battery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS: \u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTwo heating platens are controlled by a digital temperature controller up to 200°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeated Platen\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlaten Area: 120mm x 120mm\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMade of Aluminium alloy with the inserted heating element\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eWarning: Please don't press a small area die directly against the soft Aluminium alloy surface. You may add a hard steel plate on top and bottom if press a small diameter die\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMax. Working Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e200°C Max. (\u0026lt;30 minutes)\u003c\/li\u003e\n\u003cli\u003e100°C continuous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe single set point digital controller is installed in the control cabinet\u003c\/li\u003e\n\u003cli\u003eTemperature accuracy ±1°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMax. Working Pressure\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e6 Metric Ton (Note: the machine base must be secured to an unmovable \u0026amp; solid table before operation)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMax. Opening \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e30 mm between two heating plates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eGauge Pressure Value to Force Conversion\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eGauge Displayed Pressure Value (Mpa)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6 \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e24\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e30\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e36\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eActual Force Applied on the Hydraulic Cylinder (Ton)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eNotes: \u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eThe actual force applied to the Hydraulic Cylinder (Ton) is equal to the force applied to your working piece\u003c\/li\u003e\n\u003cli\u003eFor calculating the actual pressure (MPa) applied to your working piece, please follow the equations below:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eP = T\/(πr^2) x g x 10\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eP: Pressure (MPa) applied to your working piece\u003c\/li\u003e\n\u003cli\u003eT: Force (Ton) applied to the Hydraulic Cylinder \u003c\/li\u003e\n\u003cli\u003eg: Standard gravity. g ≈ 9.8 m\/s\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eπ: ~3.14\u003c\/li\u003e\n\u003cli\u003er: Radius (cm) of the working piece\u003c\/li\u003e\n\u003cli\u003e*1 Metric Ton = 1000 kg; 1 MPa ≈ 10 kg\/cm\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e110VAC or 220VAC +\/-10%, 50\/60Hz, single-phase (please select the voltage in the selection bar)\u003c\/li\u003e\n\u003cli\u003e1200 W max,15A circuit breaker is required \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOption\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eUpgrade to Digital Pressure Gauge (100Kp to 60Mp) with $600 extra (Pic.1 \u0026amp; 2)\u003c\/li\u003e\n\u003cli\u003eWe may install a digital load cell between the hot plate and hydraulic cylinder ( click Pic. 3 \u0026amp; 4 to order)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ca href=\"https:\/\/mtimalaysia.com\/products\/DHPG\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/HPG6Main_b92e31cc-a808-4917-b742-0154062ea179.jpg?v=1764854231\u0026amp;width=3840\" alt=\"Digital Pressure Gauge, M14 x 1.5 from - Optional 30\/60MPa - DHPG\" width=\"62\" height=\"41\"\u003e\u003c\/a\u003e Pic. 1 \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP60-LDmain.jpg\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP60-LDmain.jpg\" width=\"74\" height=\"49\"\u003e\u003c\/a\u003e Pic. 2 \u003ca href=\"https:\/\/mtimalaysia.com\/products\/LC-KIT-5\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/mtimalaysia.com\/cdn\/shop\/files\/EQ-LC-KIT-5_Main_27a71941-efa2-4e75-b072-baa1e8ca706c.jpg?v=1764850688\u0026amp;width=3840\" alt=\"0- 5T Pressure Calibration Kit: Load cell + Load cell Mount + Digital Meter - LC-KIT-5\" width=\"66\" height=\"44\"\u003e\u003c\/a\u003ePic. 3 \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/6Tnewmainblue.1.jpg\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/6Tnewmainblue.1.jpg\" width=\"74\" height=\"49\"\u003e\u003c\/a\u003ePic. 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCompliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE Certified \u003c\/li\u003e\n\u003cli\u003eUL \/ CSA Certification is available upon request at extra cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"MTI","offers":[{"title":"110VAC","offer_id":44985169641611,"sku":"YLJHP60V110","price":0.0,"currency_code":"MYR","in_stock":false},{"title":"220VAC +\/-10%","offer_id":44985169674379,"sku":"YLJHP60V220","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/6Tnewmainblue_5a80dd81-8347-41d8-89cc-bb27a89451a7.jpg?v=1764854923","url":"https:\/\/mti-indonesia.com\/products\/ylj-hp60-ld","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}