{"product_id":"ylj-hp80","title":"9 KN (+\/- 5N) Lamination Hot Press (200x150 mm) up to 150C with Precision Pressure Controller - YLJHP80","description":"YLJ-HP80 is a Pneumatic Press with a precision constant pressure controller within +\/- 0.5 Kg up to 9KN and 150°C. It is designed for testing the effect of pressure on solid-state battery performance, and also can be used as the SEI formation or electrode lamination under hot pressing. This device is Ar gas compatible and can be used in the glovebox. SPECIFICATIONS: Pneumatic Press Max. Load: 9KN ( 900 Kg) Pneumatic cylinder travel distance 200 mm Max. Working area: 200 mm W x 150 mm D Max. working height: 0 - 110 mm Driven by any standard air compressor or inert gas tank, which is not included. 0.4~0.8Mpa of air pressure supply is needed. Please click the picture below to order. If alignment for upper and bottom plates is not ideal, please slightly adjust the four screws at corners. Attention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. Click here to learn about the installation of a gas regulator. Note: If used in the glove, an inert gas cylinder must be used for the gas source. pic1 pic2 Heating Plates Two heating plates with two independent single point temperature controllers Single point PID temperature control with +\/- 1ºC accuracy Heated plate area: 200 mm W x 150 mm D Max. working temperature: 200°C (continuous) Heating Rate: 10°C\/ minute Max. Power: 208 - 240V V (50\/60 Hz), 1200 W, Single phase To use at 110VAC, you need order a 1500W transformer ( Click picture left to order ) Pressure Controller Pneumatic cylinder bore size 125mm diameter. Digital pressure controller with PID tuning, which can keep the constant pressure at setting value. 30 segments programmable. (max working time: 9999 minutes for each segment) Pressure Accuracy: +\/- 0.5 kg \/cm2 Optional: You may order the load cell below to calibrate the applied pressure force from time to time Feed-Through (Optional) If the press is used in a glove box, two separate feed-throughs are required One feed-through for gas tubes.($295.00\/set) One feed-through for power and communication cords.($500.00\/set) The feed-throughs are not included in the standard package, please contact us for more information. Compliance CE approval NRTL or CSA certification is available upon request at an extra cost of $3500.00 Calibration: Please use NIST certified load sensor to calibrate the pressure by yourselves. ( Please click the picture below to order: Application Notes It can be used as a jig for compressing pressure adjustable split test cell, please click the picture below for details: compress-able coin cell Compress-able pouch cell\u003cbr\u003e\u003cbr\u003e\u003ctable cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Press\u003cbr\u003e\u003cbr\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP80_Description.jpg?v=1706137058\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/YLJ-HP80_Description_100x100.jpg\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eMax. Load: 9KN ( 900 Kg)\u003c\/li\u003e\n\u003cli\u003ePneumatic cylinder travel distance 200 mm Max.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWorking area: 200 mm W x 150 mm D\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMax. working height: 0 - 110 mm\u003c\/li\u003e\n\u003cli\u003eDriven by any standard air compressor or inert gas tank, which is not included. 0.4~0.8Mpa of air pressure supply is needed. Please click the picture below to order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eIf\u003c\/span\u003e\u003cspan\u003e alignment for upper and bottom plates is not ideal, please slightly adjust the four screws at corners.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e              \u003c\/span\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/alignment_adjustment_for_HP-80.png?v=1737767262\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/alignment_adjustment_for_HP-80_100x100.png?v=1737767262\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cspan\u003e     \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cem\u003eAttention: If a gas cylinder is used instead of an air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. \u003ca href=\"CGA-580-LD\" rel=\"noopener\" target=\"_blank\"\u003eClick here to learn about the installation of a gas regulator.\u003c\/a\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote: If used in the glove, an inert gas cylinder must be used for the gas source.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ca href=\"CGA-580-LD\" rel=\"noopener\" target=\"_blank\"\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQGRCGA580_100x100.jpg\"\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/a\u003e\u003cem\u003e\u003cstrong\u003e pic1 \u003cem\u003e\u003cstrong\u003e\u003cem\u003e\u003cstrong\u003e\u003ca href=\"ACPHD-3-LD\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQACPHD3.3_100x100.jpg\"\u003e\u003c\/a\u003e pic2\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/em\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHeating Plates\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"tf-220110-1500-ld\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/300wtransf1_a9d91d73-21ac-4721-b312-f4634e175a98_100x100.jpg?v=1713396606\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo heating plates with two independent single point temperature controllers \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eSingle point PID temperature control with +\/- 1ºC accuracy\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeated plate area: 200 mm W x 150 mm D\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMax. working temperature: 200°C (continuous)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating Rate: 10°C\/ minute Max.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower: 208 - 240V V (50\/60 Hz), 1200 W, Single phase\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTo use at 110VAC, you need order \u003ca href=\"tf-220110-1500-ld\" rel=\"noopener\" target=\"_blank\"\u003ea 1500W transformer\u003c\/a\u003e ( Click picture left to order )\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Controller\u003cbr\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQREG1050.jpg?v=1706220471\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQREG1050_100x100.jpg\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePneumatic cylinder bore size 125mm diameter.\u003c\/li\u003e\n\u003cli\u003eDigital pressure controller with PID tuning, which can keep the constant pressure at setting value.\u003c\/li\u003e\n\u003cli\u003e30 segments programmable. (max working time: 9999 minutes for each segment)\u003c\/li\u003e\n\u003cli\u003ePressure Accuracy:\u003cstrong\u003e +\/- 0.5 kg \/cm2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional: You may order the load cell below to calibrate the applied pressure force from time to time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeed-Through (Optional)\u003cbr\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/FeedtrhoughKF40installation.jpg?v=1706219580\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/FeedtrhoughKF40installation_50x50.jpg?v=1706219580\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/a\u003e\u003ca class=\"MagicThumb\" href=\"https:\/\/mti-kjgroup.com\/images\/products\/detail\/FeedtrhoughKF40installation.jpg\" id=\"mt-458516183112\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eIf the press is used in a glove box, two separate feed-throughs are required\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eOne feed-through for gas tubes.($295.00\/set)\u003c\/li\u003e\n\u003cli\u003eOne feed-through for power and communication cords.($500.00\/set)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eThe feed-throughs are not included in the standard package, please contact us for more information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003cbr\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCE approval\u003c\/li\u003e\n\u003cli\u003eNRTL or CSA certification is available upon request at an extra cost of $3500.00\u003c\/li\u003e\n\u003cli\u003eCalibration: Please use NIST certified load sensor to calibrate the pressure by yourselves. ( Please click the picture below to order:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Notes\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eIt can be used as a jig for compressing pressure adjustable split test cell, please click the picture below for details:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ca href=\"PSC\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/EQPSC.1_100x100.jpg\"\u003e\u003c\/a\u003e\u003cstrong\u003e compress-able coin cell \u003cstrong\u003e\u003ca href=\"PSPC\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" border=\"0\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0638\/4664\/6008\/files\/splipouchcell1_100x100.jpg\" title=\"\"\u003e\u003c\/a\u003eCompress-able pouch cell\u003c\/strong\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MTI","offers":[{"title":"Default Title","offer_id":44985070551179,"sku":"YLJHP80","price":0.0,"currency_code":"MYR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/4405\/3643\/files\/YLJ-HP80_Main_b2e086f6-2aa4-4fc4-be1e-43ab04b85171.jpg?v=1764853999","url":"https:\/\/mti-indonesia.com\/products\/ylj-hp80","provider":"MTI Malaysia \u0026 Indonesia","version":"1.0","type":"link"}