Automatic Flammable Gas Control and Disposal Device GSL-KR100

Automatic Flammable Gas Control and Disposal Device GSL-KR100

Device Only
RM0.00 MYR
Sale price  RM0.00 MYR Regular price 
Skip to product information
Automatic Flammable Gas Control and Disposal Device GSL-KR100

Automatic Flammable Gas Control and Disposal Device GSL-KR100

SKU: automatic-flammable-gas-control-and-disposal-device-gsl-kr100

Price: RFQ

Description

GSL-KR100 is a combustion gas module to dispose of residual flammable gas via a self-ignition heating coil. It is designed to pair with any MTI tube and atmosphere furnaces. It can also control the gas flow rate and communicate with a Honeywell hydrogen gas detector. It is a good choice for experiments under a reducing environment, such as hydrogen flow. The device also has an RJ45 ethernet port for remote control and monitoring. SPECIFICATIONS Power 200W Voltage 110V, 208-240 VAC, Single Phase, 50/60 Hz Features Applicable to dispose of various residual flammable gas along the exhaust line (designated gas needs to be discussed with MTI in advance). Compact, modularized, and compatible with various MTI furnaces. Interlocks: in case of emergency, the gas flow and furnace heating will be cut off. a flammable gas leak is detected Failure of a self-ignition heating coil Overpressure Out of flammable gas flow. One check valve to prevent gas backflow. Two solenoid valve allows users to choose the flow type, inert or flammable. One mass flow controller, 0-1000 sccm. Double explosion protection: P ressure sensor and mechanical pressure relief valve. Constant pressure mode. Automated hydrogen treatment. Remote control, data monitoring, and log. Furnace tube gas purging Flow rate 0-1000 sccm Gas Inlet Two 1/4" compression tube fittings for both inert and flammable gas. Hydrogen Gas Detector The hydrogen gas detector is connected to the control box. The alarm is preset at 20% LEL for hydrogen. If alarmed, the hydrogen gas flow and furnace heating function will be cut off. PC Control All operations need to be completed on the host computer Manual purging and automatic purging modes are available Constant pressure sintering mode: During the heating process, the control system will automatically adjust the air intake and output to keep the heating furnace in a slightly positive pressure state. (Range: 100,000pa-115,000pa) Over Pressure Protection The electronic pressure transmitter will turn on the exhaust valve to accelerate the exhaust if the set pressure reached Mechanical overpressure exhaust valve (0.4 bar relative pressure) Dimension 500L × 450W × 750H (mm) Net Weight ~15Kg Safety WARNING If equipped with a tube furnace, a metallic mesh cover must be installed at both ends of the furnace tube in case of emergency The furnace and the combustion equipment must be placed in a well-ventilated place, or in a fume hood The hydrogen detector must be installed Operators must be trained by qualified technicians & follow the safety guideline of the laboratory Warranty One-year limited warranty (The warranty does not cover consumable parts such as heating elements, processing tubes, and o-rings, please order the replacement at related products from MTI.) GSL-KR200 is a combustion gas module to dispose of residual flammable gas via a self-ignition heating coil. It is designed to pair with any MTI tube and atmosphere furnaces. It can also control the gas flow rate and communicate with a Honeywell hydrogen gas detector. It is a good choice for experiments under a reducing environment, such as hydrogen flow.

Power
  •  200W
Voltage
  • 110V, 208-240 VAC, Single Phase, 50/60 Hz
Features
  • Applicable to dispose of various residual flammable gas along the exhaust line (designated gas needs to be discussed with MTI in advance).
  • Compact, modularized, and compatible with various MTI furnaces. 
  • Interlocks: in case of emergency, the gas flow and furnace heating will be cut off. 
    • a flammable gas leak is detected
    • Failure of a self-ignition heating coil
    • Overpressure
    • Out of flammable gas flow. 
  • One check valve to prevent gas backflow. 
  • Two solenoid valve allows users to choose the flow type, inert or flammable. 
  • One mass flow controller, 0-1000 sccm. 
  • Double explosion protection: Pressure sensor and mechanical pressure relief valve. 
  • Constant pressure mode. 
  • Automated hydrogen treatment. 
  • Remote control, data monitoring, and log. 
  • Furnace tube gas purging
Flow rate
  • 0-1000 sccm
Gas Inlet
  • Two 1/4" compression tube fittings for both inert and flammable gas.
Hydrogen Gas Detector
The hydrogen gas detector is connected to the control box. The alarm is preset at 20% LEL for hydrogen. 
If alarmed, the hydrogen gas flow and furnace heating function will be cut off. 
          
PC Control

  • All operations need to be completed on the host computer
  • Manual purging and automatic purging modes are available
  • Constant pressure sintering mode: During the heating process, the control system will automatically adjust the air intake and output to keep the heating furnace in a slightly positive pressure state. (Range: 100,000pa-115,000pa)
Over Pressure Protection
  • The electronic pressure transmitter will turn on the exhaust valve to accelerate the exhaust if the set pressure reached
  • Mechanical overpressure exhaust valve (0.4 bar relative pressure)
Dimension
  • 500L × 450W × 750H (mm)
Net Weight
  • ~15Kg
Safety WARNING
  • If equipped with a tube furnace, a metallic mesh cover must be installed at both ends of the furnace tube in case of emergency
  • The furnace and the combustion equipment must be placed in a well-ventilated place, or in a fume hood
  • The hydrogen detector must be installed
  • Operators must be trained by qualified technicians & follow the safety guideline of the laboratory
Warranty 
  • One-year limited warranty (The warranty does not cover consumable parts such as heating elements, processing tubes, and o-rings, please order the replacement at related products from MTI.)