Skip to product information
Larger Digital Temperature Controlled Recirculating Water Chiller with 58L / min Flow, 17K BTU/hr - KJ6200

Larger Digital Temperature Controlled Recirculating Water Chiller with 58L / min Flow, 17K BTU/hr - KJ6200

SKU: kj6200

Price: RFQ

Specifications

KJ6200 recirculating chiller provides a clean, reliable source of temperature-controlled fluid for both open tanks and closed loop systems up to 58L/min ( 15 G/min ). It eliminates scale buildup, sewerage cost, and tap water cooling expenses. This recirculating chiller provides high cooling at low cost and has a convenient digital reading and setting display. The standard magnetic drive centrifugal pump quietly produces high flow at moderate pressure. Positive displacement pump models provide less flow but have higher adjustable pressure for more demanding applications. Chiller has a temperature stability of ± 0.3°C and four wheels on the bottom for easy moving. The temperature range can be adjusted from 5 to 35°C. It is suitable for MTI CZ crystal growing, larger tube furnaces, high power induction heaters SPECIFICATIONS Power Supply AC 208 -240V, single-phase, 2.12 kW Both 50 Hz and 60 Hz are available. Cooling Capacity 5004W (17500Btu/hour) Compressor Rotary Compressor (1.68 KW) Refrigerant R410a, 1.2 kg Temperature Control 5~30 °C Temperature Accuracy ± 0.3 °C Heating Exchanger Stainless steel Water Flow Rate (Head Pressure) 58 Liter / minute ( 28 meters high, 40psi ) Water Tank 15 Liters made of stainless steel The water chiller should not be connected to a system with a capacity more than the tank's capacity itself. Distilled water is required as the coolant. Do not use deionized water as the cooling agent, DI water may cause the piping corrosion, mainly pitting, and leak over time. Pipe Connection Φ12mm push-to-connect. 8mm I.D, 12mm O.D. polyurethane tube is included Water Filter One water filter is included for immediate use. Replace the water filter every 3 to 6 months based on water quality and usage. Please click the pictures below to learn more. Noise 80dBA at 0.25 m away. Protection Protected from over-temperature and Min 2 L/min water flow Operation Instructions Compliance CE approval NRTL or CSA Certification (UL 1450) is available upon request at extra cost, please contact our sales representatives for a quote. Application Notes Use of tap water is prohibited. Please connect the chiller water outlet to the equipment water inlet and the chiller water inlet to the equipment outlet. Otherwise, the water flow sensor on the equipment may fail to work due to the wrong water flow direction STANDARD PACKAGE No. Description Qty Picture (Click to enlarge) 2 Water pipe 3 3 Alarm connecter 1 4 Outfall washer 2 5 Sealing tape 1 6 Fixing screw and washer 4 7 Tighten wrench 1

Power Supply AC 208 -240V, single-phase, 2.12 kW
Both 50 Hz and 60 Hz are available. 
Cooling Capacity 5004W (17500Btu/hour)
Compressor Rotary Compressor (1.68 KW)
Refrigerant R410a, 1.2 kg
Temperature Control 5~30 °C
Temperature Accuracy ± 0.3 °C
Heating Exchanger Stainless steel
Water Flow Rate (Head Pressure)
58 Liter / minute ( 28 meters high, 40psi )
Water Tank
  • 15 Liters made of stainless steel
  • The water chiller should not be connected to a system with a capacity more than the tank's capacity itself.
  • Distilled water is required as the coolant.
  • Do not use deionized water as the cooling agent, DI water may cause the piping corrosion, mainly pitting, and leak over time.
Pipe Connection
  • Φ12mm push-to-connect.
  • 8mm I.D, 12mm O.D. polyurethane tube is included
Water Filter
  • One water filter is included for immediate use.
  • Replace the water filter every 3 to 6 months based on water quality and usage. Please click the pictures below to learn more.
Noise
80dBA at 0.25 m away. 
Protection
Protected from over-temperature and Min 2 L/min water flow
Operation Instructions
Compliance
  • CE approval
  • NRTL or CSA Certification (UL 1450) is available upon request at extra cost, please contact our sales representatives for a quote. 
Application Notes
  • Use of tap water is prohibited.
  • Please connect the chiller water outlet to the equipment water inlet and the chiller water inlet to the equipment outlet. Otherwise, the water flow sensor on the equipment may fail to work due to the wrong water flow direction
,
No. Description Qty Picture (Click to enlarge)
2 Water pipe 3
3 Alarm connecter 1
4 Outfall washer 2
5 Sealing tape 1
6 Fixing screw and washer 4
7 Tighten wrench 1

You might also like...