Skip to product information
Short Circuit Test System for Pouch Cell Under Variable Pressure 0 - 600kg - MSK-TE910

Short Circuit Test System for Pouch Cell Under Variable Pressure 0 - 600kg - MSK-TE910

SKU: short-circuit-test-system-for-pouch-cell-under-variable-pressure-0-600kg-msk-te910

Price: RFQ

Specifications

MSK-TE910 Short Circuit Test System allows for testing pouch cell or its battery pack with adjustable temperature and pressure. Such a system has two test methods which are auto-mode and manual-mode. What's more, this machine tests insulation resistance precisely to recognize the micro circuit status of the battery in order to test the safety issue of the battery. SPECIFICATIONS Features Adjustable temperature control Adjustable pressure control Working Voltage AC220V±10% 50/60Hz Working Pressure 0~900Kg ±3Kg Working Distance 0-80mm Working Temperature Upper and Lower Platen:130ºC±5ºC Max. Pouch Battery Size 300 x 300 x 70mm Max. Short Circuit Auto alarm Testing Input Voltage DC 0~500V adjustable Max. Measurable Leakage Current 50 uA Resistivity Measurement Range Max. 199MΩ Testing Period 0~99 Seconds adjustable (2~3 seconds is suggested) Air Pressure 0.1Mpa~0.7Mpa is suggested. Air Compressoris not included. please click here to order or order from your local hardware store. Attention: If a gas cylinder is used instead of air compressor(pic2), a two-stage pressure regulator(pic1) must be installed on the gas cylinder to limit the pressure within the required working range for safe operation. Click here to learn the installation of a gas regulator. pic1 pic2 Yields <600pcs/hour Application Notes Please Click Here for Details on UN38.3 Li-Ion Battery Testing Requirements IEC 62113 Safety Test Standard Details Other equipment for testing of IEC 62113 or UN38.3 Standards can be found at MTI online web.


Features
  • Adjustable temperature control
  • Adjustable pressure control
Working Voltage
  • AC220V±10% 50/60Hz
Working Pressure
  • 0~900Kg ±3Kg
Working Distance
  • 0-80mm
Working Temperature
  • Upper and Lower Platen:130ºC±5ºC Max.
Pouch Battery Size
  • 300 x 300 x 70mm Max.
Short Circuit
  • Auto alarm
Testing Input Voltage
  • DC 0~500V adjustable
Max. Measurable Leakage Current
  • 50 uA
Resistivity Measurement Range
  • Max. 199MΩ
Testing Period
  • 0~99 Seconds adjustable (2~3 seconds is suggested)
Air Pressure
Yields
  • <600pcs/hour

Application Notes